2007-C7-1 - Ageing, Diagnostics and Maintenance
2007-C7-1-1
LE ROY Séverine, BOUFAYED Fakher, BAUDOIN Fulbert, TEYSSEDRE Gilbert, LAURENT Christian - Laboratoire Plasma et Conversion d'Ãnergie, Université Paul Sabatier Toulouse, France
2007-C7-1-2
Development of diagnostic procedures for XLPE cables with water trees
FOOTTIT Frith, LYALL Jim, OYEGOKE Bolarin, BIRTHWHISTLE David - Queensland University of Technology (QUT) Australia
2007-C7-1-3
Effect of cross-linking and antioxidant on the conductivity of the polyethylene
HOUABES M. - University Badji Mokhtar of Annaba Algeria
2007-C7-1-4
Annealing effect on the conductivity of XLPE insulation in power cable
BELANA Juan, ÃRRIT Jordi, DIEGO José Antonio, MUDARRA Miguel - Universidad de Catalunya (ETSEIAT) Barcelona, Spain
FRUTOS Fabián, ACEDO Miguel - Universidad de Sevilla (ETSII) Spain
2007-C7-1-5
Effect of the dielectric strength test on dielectric properties
TAMUS Z. Ã., NEMETH E. N - Budapest University of Technology Hungary
2007-C7-1-6
Space charge measurements in XLPE insulated mid-voltage cable: correlation with cable performance
TAMAYO Idalberto, ÃRRIT Jordi, DIEGO José Antonio - Universidad Politècnica de Catalunya (ETSEIAT) Barcelona, Spain
2007-C7-1-7
Water treeing test results for different XLPE compounds obtained with needle techniques
SHUVALOV Mikhail, OVSIENKO Vladimir, OBRAZTOV Yuri - VNIIKP Moscow, Russia
URBANCZYK Andrzej - Borealis Poznan, Poland
BOSTRÃM Jan-Ove - Borealis AB Stenungsund, Sweden
2007-C7-1-8
Crosslinking and water treeing in polyethylene insulation
CIUPRINA Florin - ELMAT lab. Politehnica University of Bucharest Romania
FILIPPINI Jean César, TEISSEDRE Gisèle - LEMD-CNRS / UJF Grenoble, France
CAMPUS Alfred, SMEDBERG Annika - Borealis AB Stenungsund, Sweden
2007-C7-1-9
HVIDSTEN Sverre, FAREMO Hallvard, SELSJORD Mildrid - SINTEF Energy Karl Stenungsund, Sweden
JÃGER Michael, SMEDBERG Annika, NILSSON Ulf H. - Borealis AB Stenungsund, Sweden
KVANDE Stine - NTNU, Dept. of Physics Trondheim, Norway
KALKNER Wilfried - Technische Universität Berlin Germany
2007-C7-1-10
Exploring the water treeing inhibition effect of antioxidants for XLPE insulation
MATEY Gabriel, LABBE Dennis - Products and Marketing Ltd Geneva, Switzerland
2007-C7-1-12
STANCU Christina, NOTINGHER Petru - Politehnica University of Bucharest Romania
NOTINGHER P. jr, CASTELLON Jérôme, AGNEL Serge, TOUREILLE Alain - LEM, Université de Montpellier 2 France
RAKOWSKA Aleksandra, SIODLA Krzysztof - Technical University of Poznan Poland
2007-C7-1-13
Water treeing at high hydrostatic pressure and temperatures
FAREMO Hallvard, HVIDSTEN Sverre, BENJAMINSEN Jan Tore - SINTEF Energy Research Trondheim, Norway
BÃRNES Atle Harald - Statoil ASA Bergen, Norway
2007-C7-1-14
HAMPTON Nigel, HARTLEIN Richard - NEETRAC, Georgia Institute Atlanta, USA
2007-C7-1-15
A molecular approach to the electrical aging of XLPE cables
CRINE Jean-Pierre - Technology Consultant lso with Ecole Polytechnique de Montréal St Bruno, Canada
CRINE Jean-Pierre - Technology Consultant lso with Ecole Polytechnique de Montréal St Bruno, Canada
2007-C7-1-16
Kinetic modelling of phenol stabiliser efficiency in polyethylene submitted to nuclear environments
RICHAUD Emmanuel, COLIN Xavier, AUDOUIN Ludmila, VERDU Jacques - LIM-ENSAM de Paris France
MONCHY-LEROY Carole - EDF R&D Moret-sur-Loing, France
2007-C7-1-17
REUTER Mark, GOCKENBACH Ernst, BORSI Hossein - Schering Inst., Leibnitz Universität Hannover, Germany
2007-C7-1-18
Understanding and optimization of long term ageing in cable industry
STUHLDREIER Thomas, FOURNIER Jérôme - Nexans Research Center Lyon, France
PLANES Ãmilie - MATEIS UMR CNRS 5510 INSA Lyon France
2007-C7-1-19
Electrical and physico-chemical analysis of Belgium medium voltage cables data bank
CASTELLON Jérôme, AGNEL Serge, NOTINGHER Petru jr, TOUREILLE Alain - IES-UM2, Université de Montpellier France
BEAUGUITTE Dimitri, PLATBROOD Gérard, TITS Yvan - Laborelec Linkebeek, Belgium